Agilent Technologies FS2101 Manuale Utente

Pagina di 48
 
 
The following error messages are reported by the PCI 
inverse assembler. 
Error
 
Messages
 
ERROR-NO DEVICE SELECTED 
This error is displayed during a non special cycle data phase 
when IRDY and TRDY are asserted and DEVSEL is not 
asserted. 
ERROR DEVSEL ASSERTED 
This error is displayed during a special cycle data phase if 
DEVSEL is asserted. 
SYSTEM ERROR 
This error is displayed anytime SERR# is asserted. 
 
The INVASM OPTIONS feature is not included with the PCI 
Active Analysis Probe software.  The same or better capability 
for post processing acquired data can be achieved using the 
16505A Pattern Filters. 
INVASM OPTIONS 
  
Setting up the 
Analyzer to use the 
PC Mapper Inverse 
Assembler
 
After the configuration file is loaded the PCI PC Mapper software 
can be loaded: 
1.  Install the PCI  Analysis Probe software flexible diskette 
in the disk drive of the logic analyzer. 
2.  Configure the menu to “Load” the analyzer that is 
connected to the PCI Active Analysis Probe with the file 
names IAP64EXM. 
3.  Execute the load operation to load the file into the logic 
analyzer. 
 
 
Data can be acquired by touching the  RUN button.  As soon as 
there is activity on the bus, the logic analyzer will begin to 
acquire data.  The analyzer will continue to acquire data and will 
display the data when the analyzer memory is full, the trigger 
specification is     TRUE or when you touch STOP. 
Acquiring Data 
The logic analyzer will flash “Slow or Missing Clock” if the PCI  
Clock signal is not being detected by the logic analyzer. In this 
case, check the logic analyzer to PCI Active Analysis Probe 
connection (refer to your User’s Manual). 
 
                                                                         25