Moyer Diebel 401-HTM2 PLUS Manuale Utente

Pagina di 51
4
GENERAL
Accessories
17RS - 17" rack stand (raises working height and adds rack storage)
17T - 17" cabinet (raises working height and adds storage)
CST - Combination sink/table (scraping and sorting station)
101285 - Dish Rack (Peg Rack)
101273 - Silverware Rack (Flat Bottom Rack) 
Electrical Power Requirements
Booster
Machine
Power Requirement
Model
Voltage
Rise
Full Load Amp
(125% Service Factor)
401-LT PLUS
115/60/1
N/A
9
15
401-HTN PLUS
115/60/1
N/A
9
15
401-HT PLUS
208/60/1
40
33
42
401-HT PLUS
240/60/1
40
37
47
401-HT PLUS
208/60/1
70
45
57
401-HT PLUS
240/60/1
70
51
64
NOTE:
208-230V/60Hz/1PH electrical supply service must be a 3-wire plus ground for connection 
as shown.
—3-Wire Plus Ground Diagram
00036
115v
115v
L
1
L
2
N
G
208-230