  3.2  Burner and nozzle characteristics table 
 
Burner 
Rated 
heating 
capacity 
(kW) 
 
LPG – G30/G31  30/37 mbar 
 
 
Nozzle 
diameter 
1/100 mm 
By-pass 
mm 
1/100 
Reduced 
flow rate 
(W) 
Flow rate  
g/h G30 
Flow rate 
g/h G31 
Auxiliary (1) 
1.05 
50 
30 * 
28 ** 
350 
76 
75 
Semi rapid (2) 
1.75 
65 
33 * 
32 ** 
450 
130 
128 
Ultra Rapid (3) 
3.4 
94 
65 * 
63 ** 
1500 
247 
243 
*/**: diameters marked * and ** must be fitted respectively on valves marked * and 
**shown in point "4.1 Adjusting the minimum setting for natural gas".
 
 
 
Burner 
Rated 
heating 
capacity 
(kW) 
 
Natural gas – G20  20 mbar 
 
 
Nozzle diameter 
1/100 mm 
Reduced flow rate 
(W) 
Auxiliary (1) 
1.05 
72 
350 
Semi rapid (2) 
1.75 
97 
450 
Ultra Rapid (3) 
3.5 
133 
1500 
 
 
 
  3.3  Arrangement of burners on cooking hob 
 
 
 
 
 
 
BURNERS 
 
1.  Auxiliary   
2.  Semi rapid  
3.  Ultra rapid