Bryant ASPAS1BBA007 Manuale Utente

Pagina di 24
6
Bryant
Section 1 — General Information
Bryant Air-cooled 7 kW, 12 kW and 15 kW Generators
1.5 SPECIFICATIONS
1.5.1 GENERATOR
Model
ASPAS1BBA007
ASPAS1BBA012
ASPAS1BBA015
Rated Max. Continuous Power Capacity (Watts*)
6,000 NG/7,000 LP
12,000 NG/12,000 LP
13,000 NG/15,000 LP
Rated Voltage
120/240
120/240
120/240
Rated Max. Continuous Load Current (Amps)
120 Volts**
50.0 NG/58.3 LP
100.0 NG/100.0 LP
108.3 NG/125.0 LP
240 Volts
25.0 NG/29.2 LP
50.0 NG/50.0 LP
54.2 NG/62.5 LP
Main Line Circuit Breaker
30 Amp
50 Amp
65 Amp
Phase
1
1
1
Number of Rotor Poles
2
2
2
Rated AC Frequency
60 Hz
60 Hz
60 Hz
Power Factor
1
1
1
Recommended Air Filter
Bryant Part # 0C8127
Bryant Part # 0C8127
Bryant Part # 0C8127
Battery Requirement
Group 26
Group 26
Group 26
(At 0
°
F -17.8
°
C)
12 Volts and 
12 Volts and 
12 Volts and
350 Cold-cranking
525 Cold-cranking
525 Cold-cranking
Amperes Minimum
Amperes Minimum
Amperes Minimum
Weight
375 Pounds
470 Pounds
487 Pounds
Output Sound Level @ 23 ft (7m) at full load
68 db (A)
70.5 db (A)
71.5 db (A)
Normal Operating Range
-20°F (-28.8°C) to 104°F (40°C)
* Maximum wattage and current are subject to and limited by such factors as fuel Btu content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases about 3.5
percent for each 1,000 feet above sea level; and also will decrease about 1 percent for each 6° C (10° F) above 16° C (60° F) ambient temperature.
** Load current values shown for 120 volts are maximum TOTAL values for two separate circuits. The maximum current in each circuit must not exceed the value stated for 240 volts.
1.5.2 ENGINE
ASPAS1BBA007
ASPAS1BBA012
ASPAS1BBA015
Type of Engine
GH-410
GT-990
GT-990
Number of Cylinders
1
2
2
Rated Horsepower
14.5 @ 3,600 rpm
30 @ 3,600 rpm
30 @ 3,600 rpm
Displacement
410cc
992cc
992cc
Cylinder Block
Aluminum w/Cast
Aluminum w/Cast
Aluminum w/Cast
Iron Sleeve
Iron Sleeve
Iron Sleeve
Valve Arrangement
Overhead Valves
Overhead Valves
Overhead Valves
Ignition System
Solid-state w/Magneto
Solid-state w/Magneto
Solid-state w/Magneto
Recommended Spark Plug
RC14YC
RC12YC
RC12YC
Spark Plug Gap
0.76 mm (0.030 inch)
0.508 mm (0.020 inch)
0.508 mm (0.020 inch)
Compression Ratio
8.6:1
9.5:1
9.5:1
Starter
12 Vdc
12 Vdc
12Vdc
Oil Capacity Including Filter
Approx. 1.5 Qts
Approx. 1.7 Qts
Approx. 1.7 Qts
Recommended Oil Filter
Bryant Part # 70185D
Bryant Part # 70185D
Bryant Part # 70185D
Recommended Air Filter
Bryant Part # 0C8127
Bryant Part # 0C8127
Bryant Part # 0C8127
Operating RPM
3,600
3,600
3,600
‹
‹
1.6
SYSTEM SET LED
The “System Set” LED is lit when all of the following
conditions are true:
1. The AUTO/OFF/MANUAL switch is set to the AUTO
position.
2. The utility voltage being supplied to the unit is being
sensed by the PCB. If the utility sense voltage is not
connected to the unit or if it is below 168 volts AC,
then the system set light will flash rapidly. This
indicates that if the AUTO/OFF/ MANUAL switch is
placed in the Auto position, the generator will start.
3. The “Not In Auto” dip switch is set to the OFF position
on the control board.
4. No alarms are present, for example, low oil pressure,
high temperature, etc.
1.7
FUEL REQUIREMENTS 
AND RECOMMENDATIONS
With LP gas, use only the vapor withdrawal 
system. This type of system uses the vapors formed
above the liquid fuel in the storage tank. The engine has
been fitted with a fuel carburetion system that meets the
specifications of the 1997 California Air Resources Board
for tamper-proof dual fuel systems. The unit will run on
natural gas or LP gas, but it has been factory set to run
on natural gas.