7.2. CV-A11 RS-232C command list. 
 
 
Command Name 
Format 
Parameter 
 
Remarks 
      A – General settings and useful commands 
EB  Echo Back 
EB=[Param.]<CR><LF>  0=Echo off 
1=Echo on 
Off at power up 
ST  Camera Status request  ST?<CR><LF> 
 
 
Actual setting 
HP  Online Help request HP?<CR><LF> 
 
 
Command list 
VN  Firmware version 
VN?<CR><LF> 
 
 
3 letter version 
      B – Timing and shutter related commands 
SC  
Scanning format 
SC=[Param.]<CR><LF>  0=full frame 
2=1/3 partial 
1=1/2 partial 
3=1/6 partial 
 
TR  Trigger mode 
TR=[Param.]<CR><LF>  0=normal 
2=Pulse width 
4=Long time 
6=Smearless 
1=Edge 
3=Frame delay 
5=Start/stop 
 
SM  Shutter mode 
SM=[Param.]<CR><LF>  0=Normal 1=Programmab. 
 
SH  Shutter speed 
SH=[Param.]<CR><LF>  0=1/30 
2=1/60 
4=1/250 
6=1/1000 
8=1/4000 
10=1/20,000 
12=1/60,000 
14=1/100,000 
1=1/50 
3=1/125 
5=1/500 
7=1/2000 
9=1/10,000 
11=1/40,000 
13=1/80,000 
 
All15 step is valid 
in normal trigger 
mode. 
 
In all trigger 
modes shutter 
speeds higher 
than 9 will result 
in 1/10,000  
PE  Programmable expos. 
PE=[Param.]<CR><LF> 
0=*1),
 1=1.5H 
1023=1023.5 H 
H= 63.56µsec 
 
 
 
 
 
 
HC  HD accumulation 
HC=[Param.]<CR><LF>  0=H synchron 
accumulation 
1=a-synchron 
accumulation 
a-sync. only for 
TR=2 and TR=3 
      C – Signals and polarity 
SO  
Sync signal 
SO=[Param.]<CR><LF>  0=no sync  
1=sync on video   
CW  Clock/WEN 
CW=[Param.]<CR><LF>  0= WEN out 
1=Clock out 
CW=0 if clock not 
used 
TP  Trigger polarity 
TP=[Param.]<CR><LF>  0= active low 
1= active high 
*2) 
WP  WEN polarity 
WP=[Param.]<CR><LF>  0= active low 
1= active high 
 
      D – Gain and analogue signals setting 
AS  
AGC Switch 
AS=[Param.]<CR><LF>  0=AGC off 
1=AGC on 
0= manual gain 
AG  AGC Level 
AG=[Param.]<CR><LF>  0=low 255=high 
Range 0 to 255 
GA  Manual gain Level 
GA=[Param.]<CR><LF>  0=low 255=high 
Range 0 to 255 
RP  Rear Potentiometer 
RP=[Param.]<CR><LF>  0=manual gain 
1=rear potm. 
 
SU  Setup Level 
SU=[Param.]<CR><LF>  0=low 255=high 
Range 0 to 255 
WC  White clip Level 
WC=[Param.]<CR><LF>  0=low 255=high 
Range 0 to 255 
GS  Gamma Select 
GS=[Param.]<CR><LF>  0=gamma 1 
1=gamma 0.45 
 
      E – Saving and loading data in EEPROM 
LD  
Load settings from 
camera EEPROM 
LD=[Param.]<CR><LF>  0=Factory data  
2=User 2 area 
1=User 1 area 
3=User 3 area 
Latest used data 
area  becomes 
default at next 
power up 
SA  Save settings to 
camera EEPROM 
SA=[Param.]<CR><LF>  1=User 1 area 
3=User 3 area 
2=User 2 area 
 
 
*1) 
PE=0  has no function in triggered mode. PE=1 is 0.5H in continuous mode 
  
*2) 
If positive logic is used (TP=1), the first trigger pulse after power up will be ignored. 
!! 
Do not try to use commands not shown in the list. 
 
 
 
 
 
 