JAI CV-A11 Manuale Utente

Pagina di 25
CV-A11
 
10. Appendix 
10.1. CV-A11 emulating CV-M10 interfacing
 
 
The CV-A11 has a slightly different pin configuration on the 12-pin Hirose connector, compared 
to the M-series. This new configuration is compliant to the EIA-J standard. This means, however, 
that the CV-A11 is not completely backward compatible with the CV-M10, CV-M40, etc in all 
cases (depending on the cable configuration). The table below shows how to change the pin 
configuration, by changing internal solder jumpers. 
Please note: Only a qualified electronics technician or engineer should make these changes. 
 
Hirose pin # 
Function 
JP2 
JP3 
JP5 
JP1 
JP4 
Remarks 
PCLK output enabled 
Short 
 
 
 
 
Note 2 
No 
connection 
Open 
     
10 
WEN output 
 
Open 
Short 
 
 
 
10 
Connected to ground 
 
Short 
Open 
 
 
 
11 
Ext Trigger input 
 
 
 
Open 
Short 
 
11 
+12V DC in 
 
 
 
Short 
Open 
 
Note 1: Configuration shown in Bold+Italic is factory default setting 
Note 2: The RS-232C command “CW” must be set to CLK 
 
 
Fig. 28. PK8304 Rear Board of CV-A11 
 
10.2. WEN out on pin 6 on 6 pin connector 
JP1     JP2 
Instead of EEN output on pin #6 on the 6 pin Hirose 
connector, WEN can be output by jumper settings. The 2 
jumpers are found on the main board PK8298B, if the 
bottom plate is removed. 
 
 
 
 
 
 
Signal on pin #6  
JP1 
JP2 
Remark 
EEN out 
Open Short  default 
WEN out 
Short Open 
 
Bold+Italic is factory default setting  
 
 
 
 
 
Fig. 29. PK8298A main board.
 
- 22 -