JAI CV-A11 Manuale Utente

Pagina di 25
CV-A11
 
6.2. Input-output of HD/VD Signals 
In the default setting the camera will accept external HD/VD signals on pin 6 and 7 of the 12 pin 
Hirose connector. If external HD/VD is applied, the camera will synchronize to it. If no external 
sync signals are applied, the camera will operate with its internal x-tal controlled sync. The 
camera scanning system should be set to the same as the external connected sync. In fig. 11 the 
time requirements to relation between VD and HD is shown.  
The input is TTL level as factory setting. It can be 75 Ohm terminated by the internal switch on 
the PK8299 board. SW2-1 for HD and SW2-2 for VD. On for 75 Ohm termination. 
To output the internal HD/VD signals on pin 6 and 7 the internal switch SW1-1 and 1-2 on the 
PK8299 board should be set ON. The output is TTL level from a 75-Ohm source. 
Refer to “7.4. Internal Switch and Jumper settings.” 
In trigger modes there are no continuous VD out. Only after an external trigger pulse, a VD pulse 
will be output. 
 
To use this mode:  
Set function: 
SW 1 on PK8299 to IN for external VD/HD input. Factory default. 
 
SW 2 on PK8299 to 75 Ω for termination of VD/HD.  
 
SW 2 on PK8299 to TTL for TTL level for VD/HD. Factory defaults. 
 
SW 1 on PK8299 to OUT for internal VD/HD output. 
Input: 
Ext. VD in or int. VD out on pin 7 on 12-pin connector.  
 
Ext. HD in or int. HD out on pin 6 on 12-pin connector.  
  
Important notes on using this mode
 
 
External sync system should follow the camera scanning system. 
 
 
 
Fig. 11. Ext. HD and ext. VD phase conditions. 
6.3. Continuous Operation (Non triggered) 
For applications that do not require asynchronous external trigger (continuous operation). This is 
the factory default setting of the camera.  
See chapter 7.1 on how to select this mode. 
 
To use this mode:  
Set function: 
Trigger mode to “Normal” 
TR=0 
 
Shutter mode “Normal” or “Programmable” 
SM=0, SM=1 
 
 
“Shutter Speed” 
SH=0 through 15 
 
“Programmable exposure” for full scanning 
PE=1 through 523 
 
PE for 1/2, 1/3 and 1/6 partial scan. 
< 275, 195, 115 
 Other 
functions 
Input: 
Ext. VD on pin 7 on 12-pin connector. If used. 
 
Ext. HD on pin 6 on 12-pin connector. If used. 
  
 
Fig. 12. Horizontal timing details and pixel numbering for the CCD array. 
 
Fig. 13. Vertical timing details and lines numbering for the CCD array.  
 
NOTE. Fig. 12 and fig. 13 are omitted
 
- 7 -