Zanussi ZCM 600 W Manuale Utente

Pagina di 28
22
Model Number:
ZCM 600W/ZCM610 X
Appliance Class 2 sub class 1 and Class 1
APPLIANCE CATEGORY: II 2H3+
APPLIANCE GAS SUPPLY: Natural Gas 20 mbar
Dimensions
Height
900 mm
Depth
595 mm
Width
597 mm
Oven Capacity
1.8 Cu. ft
Hob
Rear left burner (semi-rapid)
2.0 kW
Front left burner (rapid)
3 kW
Rear right burner (semi-rapid)
2.0 kW
Front right burner (auxiliary)
1.0 kW
Oven
Convection Heating Element
2.080 kW
Grill Element
1.880 kW
Convection Fan
30 W
Oven light
15 W
Total rating
2.125 kW
Supply voltage (50 Hz)
230-240 V
Technical Data
BURNER
RAPID
SEMI-RAPID
AUXILIARY
(large)
(medium)
(small)
POSITION
MAX
MIN
MAX
MIN
MAX
MIN
 NOMINAL THERMAL
 POWER                        kW
3.0
0.65
2.0
0.45
1.0
0.33
 NOMINAL FLOW
 RATE                         m
3
/h
0.286
0.057
0.190
0.038
0.095
0.028
 NOZZLE REFERENCE
119
Adjust.
96
Adjust.
70
Adjust.
 NOMINAL THERMAL
 POWER                        kW
2.8
0.65
2.0
0.45
1.0
0.33
 NOMINAL FLOW
 RATE                            g/h
202
43.5
144
29
72
21,5
 NOZZLE REFERENCE
86
40
71
32
50
28
NATURAL GAS
20 mbar
TYPE OF
GAS
CHARACTERISTICS
LPG GAS
28-30/37 mbar
1/100 mm
1/100 mm
VALUE = 49.92 MJ/Kg
VALUE = 37.78 MJ/m
3
Ws - 50.7 MJ/ m
3
Instructions for the Installer