Smeg GCO90XG Manuale Utente

Pagina di 20
 
 
Instructions for the installer
 
 
32 
5.3 Regulation for natural gas 
The hob has been inspected for G20 (2H) natural gas at a pressure of 
20 mbar. To allow the unit to work with this type of gas, perform the same 
operations described in paragraph “5.2 Regulation for LPG”, but choose 
the nozzles and regulate the primary air for natural gas, as shown in the 
following table and in paragraph "5.4 Regulation of primary air”. After the 
regulations have been carried out, restore the seals with sealing wax or 
equivalent material. 
 
 
Burner 
 
Rated  
heating 
capacity 
(kW) 
 
Natural gas – G20  20 mbar 
 
 
Nozzle diameter 
1/100 mm 
Reduced flowrate 
(W) 
Auxiliary (1) 
1.05 
73 
380 
Semi-rapid (2) 
1.65 
92 
380 
Rapid (3) 
3.1 
126 
750 
Ultra rapid (4) 
3.3 
130 
1200 
internal (5) 
1.05 
73 
380 
Double crown 
external (5) 
3.9 
140 
1200 
Fish pan (6) 
2.9 
123 
800 
 
5.4 Regulation for  town gas 
To allow the unit to work with this type of gas, perform the same 
operations described in paragraph “5.2
 
Regulation for LPG”, but choose 
the nozzles and regulate the primary air for town gas, as shown in the 
following table and in paragraph “5.5
 
Regulation of primary air”. 
Attention! Only units with safety valves can be used with town gas 
G110. 
 
 
Bruciatore 
 
Portata  
termica 
nominale  
(kW) 
 
Gas città – G110  8 mbar 
 
 
Diametro ugello 
1/100 mm 
Portata ridotta 
(W) 
Ausiliario (1) 
1.05 
132 
380 
Semirapido (2) 
1.65 
165 
380 
Rapido (3) 
3.1 
240 
800 
Ultra rapido (4) 
3.3 
250 
1200 
interna (5) 
1.05 
132 
380 
Doppia corona 
esterna (5) 
3.9 
290 
1200 
Pescera (6) 
2.9 
230 
800 
 
 
I valori relativi al gas città si riferiscono agli apparecchi della categoria III 1a2H3+.