RUN mode 
If the DIP-switch “PC/Run” is in position “Run”, the program in the ICOM-
200/201 is executed immediately after a reset. Debugging is not possible in 
this mode. 
 2 
Program download 
A program created with the Tiger software is downloaded into ICOM-200/201 
through the 9-pin Sub-D connector. To download the following has to be done: 
    Connect a power supply 8-12 V DC (Polarity: Inner contact = minus, 
outer contact = plus) 
    Connect ICOM-200/201 and PC with 9-pin D-Sub cable 
    Set DIP switch of ICOM-200/201 to PC mode 
    Set the reset DIP switch to „Reset“ and back to original position 
    Start download at the PC. 
Serial port 1 / Download
DB-9 plug
TXD 2 
RXD 3 
GND 5 
 