Operation 
To put your Electro-Sealer into operation, turn on the main switch.  Set the plate and 
electrode heat controls to the desired temperature.  Turn on the vacuum pump by 
using the switch located on the power cord for the pump. 
Turn on the auto switch.  This will cause the vacuum arm to pull a label from the 
hopper and move it into position until the operator depresses the foot pedal, sealing 
the label onto the garment.  The pedal must be held down until the press cycles out 
and the seal is completed.  As the press starts to rise from the garment, the foot pedal 
can be released, which resets the vacuum arm to feed another label.  In doing this, 
the machine automatically feeds another label while the operator is removing the 
garment and inserting another. 
When the label has been fed into position for sealing, it is important that the label is 
totally under the electrode so that the pressure is exerted on the adhesive coated 
label. 
The position of the vacuum arm is always the same and so to change the position of 
the label relative to the electrode, you must change the position where the hopper 
places the label on the vacuum arm.  To move the label left or right, the hopper is 
moved by loosening the lower hopper bracket, shifting the hopper in the direction 
desired, then tightening the bracket in position.   
Users Manual Electro-Sealer 7112 BR 
Operation  
  7