A.O. Smith FPSE-75 Manuale Utente

Pagina di 20
2
GET TO KNOW YOUR WATER HEATER
*CAUTION HARNESS HAS
120VAC. IN OPERATION
FIGURE 1
(
A)
VENT PIPE
(B)
ANODE
(C)
HOT WATER OUTLET
(D)
OUTLET (120 VAC)
(E)
FLUE BAFFLE
(F)
GAS SUPPLY
(G)
MAIN MANUAL GAS
SHUT OFF VALVE
(H)
GROUND JOINT UNION
(J)
DIRT LEG
(K)
OUTER DOOR
(L)
UNION
(M)
INLET WATER SHUT
OFF VALVE
(N)
COLD WATER INLET
(O)
INLET DIP TUBE
(P)
TEMPERATURE AND
PRESSURE RELIEF
VALVE
REPLACEMENT PARTS AND DELIMING PRODUCTS
Replacement parts and recommended delimer may be ordered
through authorized servicers or distributors.   Refer to the Yellow
Pages for your A. O. Smith plumber or contact the A. O. Smith
Water Products Company, 5621 W. 115th Street, Alsip, IL 60803,
1-800-433-2545.  When ordering parts, provide complete model
and serial numbers (see rating plate), quantity and name of part
desired (as listed in fig. 1).  Standard hardware items may be
purchased locally.
FPSE-75
with Hot Surface Ignition & SmartValve
®
VACUUM RELIEF
VALVE
*INSTALL PER
LOCAL CODES
(U)
SIDE VIEW OF BURNER ASSEMBLY
WATER TEMEPRATURE
ADJUSTING DIAL
SMARTVALVE
TM
CONTROL SYSTEM
(Q)
EMBLEM AND RATING
PLATE
(R)
INSULATION
(S)
VENT TERMINAL
(T)
DRAIN VALVE
(U)
IGNITER AND MAIN
BURNER
(V)
FLUE
(W)
DRAIN PAN
(X)
SMARTVALVE
TM
(Y)
CONTROL HARNESS
(Z)
AIR MIXING BOX
(AA) MOTOR & BLOWER
(BB) DISCHARGE AIR ECO