Auralex Acoustics Panels Manuale Utente

Pagina di 8
Auralex Acoustics, Inc.   ◆   800-959-3343   ◆   Fax:  317-842-2760
General guidelines for all panels:
1.  Whenever moving panels, transport them with the shortest dimension in the vertical position to reduce potential 
stress or breaking of the fiberglass. Do not move panels parallel to the floor without additional support.
2.  If light colored fabrics are used, it may be a good idea to wear white cotton gloves so dirt, grease or grime from the 
skin is not transferred to the fabric.
3.  Lay out panels with a laser level (preferred), hand level or chalk line to ensure uniform installation. If panels are 
being placed directly up against one another, use the first panel as a reference point for adjoining panels to be 
installed. 
4.  Make sure the wall has a completely flat surface to install the panels to. Shim the panels if necessary to create  
a uniform front surface.
Installation using Impaling Clips
1.  Mark the intended location of each panel on the wall.
2.  Fasten impaling clips to the wall using drywall screws, concrete anchors or shots and pins for concrete block or 
pre-cast concrete walls using the guide below. Place the impaling clips 4” from the intended edge location and 
spread them evenly across the panel. (see Figure 1.2)
Panel Size (1” or 2” thick)
Number of Clips
NOTE: Panels over 2” thick must also use 
adhesives for installation.
2’x4’
4
4’x4’
4
4’x6’
6
4’x8’
6
4’x10’
8
 
 
3.  Start the panel 3/4” higher than the intended wall location and press downward at a 45° angle toward the wall.  
(see Figure 1.1)
4.  Shim the clips as necessary to ensure the front edge of the panel is flush with adjoining panels.
5.  Do not apply excessive pressure to a single or multiple small locations on the panel so as to crush  
or dent the fiberglass core.
6.  This installation method will leave a 3/4” reveal between the top of the panel and the ceiling.
Note on adhesives:
•  The use of adhesives is highly suggested on all panel thicknesses for a secure permanent installation, though it is 
only mandatory for panels thicker than 2” or if they are being attached to the ceiling.
•   Use ONLY water-based, heavy bodied adhesives, such as Auralex’s Tubetak Pro.
•   Apply the adhesive liberally to the fiberglass and to the teeth of the impaling clip, but do not apply any adhesive 
within 3” from the edge of the panel.
Impaling Clips