Specification Revised 9/04
220824
TM
JDP47BF/CF/WF – GE Profile
™ 
 30" Drop-In Electric Range
Dimensions (in inches)
KW Rating
240V
11.6
208V
8.7
Breaker Size
240V
40 Amps
208V
40 Amps
R
Listed by 
Underwriters 
Laboratories
For answers to your Monogram,
®
 GE Profile
 or 
GE appliance questions, visit our website at
GEAppliances.com or call 
GE Answer Center
®
 service, 800.626.2000.
Optional Kits For Drop-In Electric Ranges 
(Available At Additional Cost)
Note: Cabinets installed adjacent to drop-in electric ranges must have an 
adhesion spec of at least a 194°F temperature rating.
Note: All 30" Drop-In Radiant Ranges conform to U.L. requirements for 0" 
spacing from range to adjacent walls below countertop. To reduce possibility 
of scorching the side walls above the countertop when no load is present on 
burners, it is recommended that a minimum 6" spacing from adjacent side 
wall be allowed for possible extended high-heat element operation.
Installation Information: Before installing, consult installation instructions 
packed with  product for current dimensional data.
IMPORTANT: 30" DROP-IN RANGES ARE DESIGNED TO HANG 
FROM THE COUNTERTOP. IT DOES NOT REST ON THE FLOOR. 
FOR INSTALLATION ALTERNATIVES, REFER TO INSTALLATION 
INSTRUCTIONS PACKED WITH  PRODUCT.
Maintop Filler
(Fills gap between cooktop and 
wall when unit is installed in 
30" free-standing cutout)
JXS66WW—White
JXS66CC—Bisque
JXS66BB—Black
Accessory Backguards
(Attaches to the back of range as 
a backguard when unit is installed 
in 30" free-standing cutout)
JXS37WW—White
JXS37CC—Bisque
JXD37BB—Black/Stainless
Lower Trim Kits
(When a drop-in is installed in an 
existing cutout greater than 27-1/4" 
from the counter to the cabinet 
cross-rail, a lower trim kit should 
be used to fill the gap at the 
bottom of the range)
JXS96WW—White
JXS96CC—Bisque
Acceptable Electrical Outlet 
Area Also In Adjacent
Cabinet Or Under Floor
Conduit is 40" long
Shave Raised Edge To Clear
31-1/8" Wide Control Panel
9/16
30" Min.
30" Min.
15" Min.
6" Min.  
from walls
7-1/2
2-7/8"
To Front Surface  
of Countertop 
30
36
27-1/2
25
23-3/16
If necessary,  
build upsides  
to 1-1/4" thick  
to provide  
countertop 
support
2000_drop_in.eps
26-1/2
27
20-5/8" Door  
Clearance  
From Front  
Surface of  
Countertop
24
31-1/4
30
A/B
Accessory 
Backguard
Acceptable Electrical Outlet 
Area Also In Adjacent
Cabinet Or Under Floor
Conduit is 40" long
Shave Raised Edge To Clear
31-1/8" Wide Control Panel
9/16
30" Min.
30" Min.
15" Min.
6" Min.  
from walls
7-1/2
2-7/8"
To Front Surface  
of Countertop 
30
36
27-1/2
25
23-3/16
If necessary,  
build upsides  
to 1-1/4" thick  
to provide  
countertop 
support
2000_drop_in.eps
26-1/2
27
20-5/8" Door  
Clearance  
From Front  
Surface of  
Countertop
24
31-1/4
30
A/B
Accessory 
Backguard
an Anti-Tip device. The installation 