J.  SW2 
White Balance mode SW 
Add. detail see AWB section 
VBS in 75OHM ON/OFF SW 
(For Gen-lock model) 
K.  MWB adjust button 
Line-lock Phase Adjustment   
 
 
L.  AWB push to lock button 
Detail pls. See AWB section 
M.  Power pilot LED   
N.  AC24V / DC12V Block Terminal 
 
 
1.1  Auto Iris Lens Connector 
Use the accompanying auto iris lens control connector plug. 
For auto iris lens with built-in EE amp. (VIDEO Type) 
Set the lens selector switch to ”Video” position. 
Connector cable leads 
1.Red---- power 
2.NC 
3.White-- video 
4.Black--  shielded 
For auto iris lens without EE amp. (DC Type) 
This is the external view of camera 
Set the lens selector switch to “DC” position. 
Connector cable leads 
1. 
Damping coil (-) 
2. 
Damping coil (+) 
3. 
Driving coil (+) 
4. 
Driving coil (-) 
Connect the leads as shown above; refer to the instructions of the lens. 
 
1.2  Power Terminal 
1.2.1 
AC24V/DC12V model 
This terminal accepts both AC 24V and DC 12V 
non-polarity 
 
 
 
 
 
1.2.2 
Line-Lock Phase Adjustment   
The vertical phase of the camera video signal can be matched to the phase of the 
AC power line. 
Using a dual-trace oscilloscope to observe the video output signal 
(V-rate) of the camera and adjust the Line-lock Phase control buttons 
to line up the phase of both signals 
Caution:  The adjustment must be 
made by qualified servicing 
person or system installer. 
PHASE 
Phase adjusting Buttons for Line-lock 
model.   
DC12V
 
NC 
~DC2 
 
PTL 
WB1 
WB2 
WB3 
 NC