To permit airflow, a 0.5mm gap on top and bottom should exist after device holding
drive is assembled.
drive is assembled.
•
Give FPC (Flexible Printed Circuit) cable enough length to avoid excessive tension
under shock condition.
under shock condition.
•
Snubbers are available from 3
rd
parties such as EAR (www.earsc.com). Material should
not produce any outgassing such as siloxane found in organic silicone oil.
•
Do not cover breather hole
Mechanical Dimensions
Connector Information
•
Connector is 35 pin ZIF (SMT horizontal mount, gold plate) Hirose FH26 - 35S - 0.3SHW(05)
(http://www.hirose-connectors.com/products/FH26_1.htm)
(http://www.hirose-connectors.com/products/FH26_1.htm)
•
FPC 10.8 +- 0.05mm width, 0.2+-0.03mm thickness
•
Maximum Length is 75mm
•
Single sided FPC is recommended
•
Follow Connector vendor recommendations on FPC design.
• Connector
Pinout