Intel Storage System SSR212CC SSR212CC Manuale Utente

Codici prodotto
SSR212CC
Pagina di 4
3
Front Panel
LEDs
Fault, ID, power
Back Panel
Buttons and Switches
Power button, reset button
I/O Connectors
1x RJ-45 COM B serial port, 2x RJ-45 
Ethernet ports, 1x DB-15 video 
connector, 1x 2.0 USB port, 1x stacked
PS/2 mouse/keyboard connector 
Power Receptacle
1x IEC AC per installed power 
supply module
Chassis
Form Factor
2U rack-mount chassis
Height
86.7 mm, 3.41"
Width
447 mm, 17.6"
Depth
631 mm, 24.8"
Weight
As shipped (zero drives): approximately
19.1 kg, 42 pounds; fully configured 
(twelve drives): approximately
30.4 kg, 67 pounds ; shipping 
container: 3.2 kg, 7 pounds
Color
Black plastics, silver sheet metal
Rack Support
Rail mount, compatible with four-post
rack mount only
System Cooling
Fans
Chassis includes three dual-rotor and
two single-rotor 40 mm hot-swappable
redundant system fans for cooling
the hard drives, baseboard, and SATA
host bus adapter (HBA) cards; the
power supply enclosure contains 
one 60 mm fan
Power
Configuration
500 W continuous, 1+1 redundant
power supplies; Intel® Storage System
SSR212CC ships with one 500 W 
power supply
Max AC Input Current (PS Module)
7.2 Amperes at 110 Vrms, 3.5 A at 
220 Vrms (each power supply module)
Max +3.3 V Output (PS Enclosure)
20.0 A (total combined power for
the+ 3.3 V and +5 V outputs 
should not exceed 120 W)
Max +5 V Output (PS Enclosure)
20.0 A (total combined power for
the +3.3 V and +5 V outputs should
not exceed 120 W)
Max +12 V Output1 
18.0 A (total combined power for
Current (PS Module)
the +12 V outputs should not 
exceed 360 W)
Max +12 V Output2 
18.0 A (total combined power
Current (PS Module)
for the +12 V outputs should not 
exceed 360 W)
Max +12 V Output3
18.0 A (total combined power
Current (PS Module)
for the +12 V outputs should not 
exceed 360 W)
Max -12 V Output
0.5 A (each power supply module)
Current (PS Module)
Max +5V Standby Output 
2.0 A (each power supply module)
Current (PS Module)
Environment
Ambient Temperature
Operating (system): 10° C to +35° C,
with maximum change not to exceed
10° C; non-operating (system): 
-40° C to +70° C
Relative Humidity
Non-operating: 90 percent @ 35° C 
non-condensing
Acoustics
<59 decibel average (dBA) (rack mount)
in an idle state in a normal office 
environment (23° C)
Electrostatic Discharge
15 KV per Intel test specification
Safety Compliance
Argentina
IRA
Australia/New Zealand
AS/NZS 3548 (based on CISPR 22)
Canada
UL60950, CSA 60950 (UL and cUL)
China
GB4943- CNCA certification
Europe, CE Mark
EN60950 (complies with 73/23/EEC)
Germany
GS license
International
IEC60950 (CB report and certificate)
Nordic Countries
EMKO-TSE (74-SEC) 207/94
Russia
GOST 50377-92
United States
UL– 60950, CSA 60950 (UL and cUL)
Electromagnetic Capability (Class A) (EMC)
Canada
ICES-003
China
GB 9254 - CNCA Certification
GB 17625 - (Harmonics)
CNCA Certification Europe, CE Mark
EN55022; EN55024 & 
EN6 1000-3-2;-3-3 
(complies with 89/336/EEC)
International
CISPR22
Japan
VCCI
Korea
RRL, MIC 1997-41 and 1997-42
Russia
GOST 29216-91 and 50628-95
Taiwan
CNS13438
United States
FCC, Part 15
Intel® Storage System SSR212CC Specifications, Continued