Estate egd4100sq Istruzione Sull'Installazione

Pagina di 12
9
Vent Length Chart
Install Vent System
1. (Optional) Put on safety glasses and gloves.
2. Install exhaust hood. Use caulking compound to seal exterior 
wall opening around exhaust hood.
3. Connect vent to exhaust hood. Vent must fit inside exhaust 
hood. Secure vent to exhaust hood with 4" (10.2 cm) clamp.
4. Run vent to dryer location. Use the straightest path possible. 
See “Determine Vent Length.” Avoid 90º turns. Use clamps to 
seal all joints. Do not use duct tape, screws or other fastening 
devices that extend into the interior of the vent to secure vent.
Install Leveling Legs
1. To protect the floor, use a large flat piece of cardboard from 
the dryer carton. Place cardboard under the entire back edge 
of the dryer. See illustration.
2. Firmly grasp the body of the dryer (not the top or console 
panel). Gently lay the dryer on the cardboard. 
3. Examine the leveling legs. Find the diamond marking. 
4. Screw the legs into the leg holes by hand. Use a wrench to 
finish turning the legs until the diamond marking is no longer 
visible.
5. Place a carton corner post under each of the 2 dryer back 
corners. Stand the dryer up. Slide the dryer on the corner 
posts until it is close to its final location. Leave enough room 
to connect the exhaust vent.
6. Once connection is made and dryer is in final location, remove 
corner posts and cardboard.
For mobile home use
Gas dryers must be securely fastened to the floor.
Mobile home installations require a Mobile Home Installation Kit. 
For ordering information please reference your “Dryer User 
Instructions.”
Level Dryer
Check the levelness of the dryer. Check levelness first 
side to side, then front to back.
If the dryer is not level, prop up the dryer using a wood block. Use 
a wrench to adjust the legs up or down and check again for 
levelness.
NOTE: It might be necessary to level the dryer again after it is 
moved into its final position.
Number of 
90º turns 
or elbows
Type of vent
Box or 
Louvered 
hoods
Angled
hoods
0
Rigid metal
Flexible metal
64 ft (20 m)
36 ft (11 m)
58 ft (17.7 m)
28 ft (8.5 m)
1
Rigid metal
Flexible metal
54 ft (16.5 m) 
31 ft (9.4 m)
48 ft (14.6 m)
23 ft (7 m)
2
Rigid metal
Flexible metal
44 ft (13.4 m)
27 ft (8.2 m)
38 ft (11.6 m)
19 ft (5.8 m)
3
Rigid metal
Flexible metal
35 ft (10.7 m)
25 ft (7.6 m)
29 ft (8.8 m)
17 ft (5.2 m)
4
Rigid metal
Flexible metal
27 ft (8.2 m)
23 ft (7 m)
21 ft (6.4 m)
15 ft (4.6 m)
WARNING
Excessive Weight Hazard
Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.