CONTROL THERMOSTAT - FMD-4 & FMD-5
FIG. 9 CONTROL THERMOSTAT
P2635
Location
 
The control thermostat is located at the upper left 
rear of the dispenser housing.
Test Procedure
1.  Disconnect the dispenser from the power source.
2.  Disconnect the black wire of the control thermostat 
from the black lead from the limit thermostat.
3.  Remove bulb from the tank.
4.  Check the voltage across black wire on the control 
thermostat and the white or red wire on the tank 
heater with the tank heater switch in the “ON” lower 
position with a voltmeter. Connect the dispenser to 
the power source. The indication must be:
 
a) 120 volts ac for two wire 120 volt models.
 
b) 208 volts ac for three wire 120/208 volt mod-
els. 
 
c) 240 volts ac for three wire 120/240 volt mod-
els.
 
d) 230 volts ac for two wire 230 volt models.
5.  Disconnect the dispenser from the power source.
If voltage is present as described the control thermostat 
is operating properly. Reinstall bulb into the tank.
If  voltage  is  not  present  as  described,  replace  the 
thermostat.
SERVICE (cont.)
Removal and Replacement.
1.  Remove  the  thermostat  capillary  bulb  by  firmly 
pulling-up on the capillary at the tank lid. This will 
disengage the grommet from the tank lid.
2.  Loosen the two #6-32 screws securing the ther-
mostat to the front tank mounting bracket.
3.  Disconnect the wires from the thermostat.
4.   Remove thermostat and remove the screws and 
spacers from the thermostat.
5.  Discard thermostat.
6.  Install two spacers and two #6-32 screws on the 
new thermostat. 
7.  Position the thermostat on the botttom side of the 
front tank mounting bracket and tighten the two 
#6-32 screws. 
8.  Slide the grommet to the line 4.5” above the bulb 
on the new capillary tube.
9.  Insert the capillary bulb through the hole in the tank 
lid and press the grommet firmly and evenly so that 
the groove in the grommet fits into the tank lid.
10. Carefully bend the capillary tube so that the tube 
and bulb inside the tank are in the vertical position 
and away from any electrical connections.
11. Refer to Fig. 10 and reconnect the wires. 
NOTE - The capillary tube must be clear of any electrical 
termination and not kinked.