Bunn single multi-brewwise dbc Guida Al Funzionamento

Pagina di 50
Page 38
FACTORY DEFAULTS
This function allows the operator to erase all of the
previously entered recipes and ad messages. Factory-
set default values will replace all previous settings.
Procedure to set factory defaults:
1. Press and hold the ® pad until WARMER OFF
appears. Release the ® pad.  Press and release ®
until the display reads FACTORY DEFAULTS.
2. Pressing NO in this screen will revert to the MAIN
SCREEN.  Press YES to replace the defaults.  This
advances to WILL REPLACE ALL BREWING SET-
TINGS
.  This screen will alternate with ARE YOU
SURE?
.
3. Pressing NO in the confirmation screen will revert
to MAIN SCREEN, without resetting the brewing
setups to the defaults. Press YES to load the
defaults. This will then revert to the MAIN SCREEN,
and the factory default values will replace all
previously entered values. It will NOT reset the
summation Brew counter.
P2312
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
FACTORY DEFAULT VALUES
Brew Lockout
NO
DEFAULT (NO NAME) SETTINGS:
Iced Coffee
BREW VOLUME
1800 mL
DILUTION VOLUME
0 mL
PULSE BREW TIME
None
PREINFUSION TIME
1st 0:53,OFF 0:45
DRIP OUT TIME
1:00
Hot Coffee
Half Batch
Full Batch
BREW VOLUMES
900 mL
1800 mL
DILUTION VOLUMES
0 mL
0 mL
PULSE BREW TIMES
None
None
PREINFUSION TIMES
1st 0:15,Off 1:00
None
DRIP OUT TIMES
0:30
0:45
Iced Tea
BREW VOLUMES
2800 mL
DILUTION PERCENTAGE
53%
PULSE BREW TIMES
None
PREINFUSION TIMES
None
DRIP OUT TIMES
0:45
ENABLE ADS
YES
BREW TEMPERATURE
93˚C (200˚F)
READY TEMPERATURE
91˚C (195˚F)
REFILL
155
SPRAY (Ml/MINUTE)
1160
DILUTE (Ml/MINUTE)
730
FUNNEL LOCKOUT
NO
UNITS
METRIC
37467  110904