Figure 7: Installing a Mini-PIM in an SRX Series Services Gateway
7.
Using a 1/8-in. (3-mm) flat-blade (–) screwdriver, tighten the screws on each side of
the Mini-PIM faceplate.
8.
Insert the appropriate cables into the cable connectors on the Mini-PIM.
9.
If necessary, arrange the cables to prevent them from dislodging or developing stress
points:
Secure the cables so that they are not supporting their own weight as they hang to
the floor.
Place any excess cables out of the way in neatly coiled loops.
Use fasteners to maintain the shape of the cable loops.
10.
Reconnect the power adapter to the device. Verify that the Power LED glows steadily
green after you press the power button.
11.
Verify that the Mini-PIM LED on the system dashboard glows steadily green to confirm
that the Mini-PIM is online.
Related
Documentation
Removing a Mini-Physical Interface Module from the SRX Series Services Gateway
CAUTION:
The Mini-PIMs available on the SRX Series Services Gateway are
not hot-swappable. You must power off the device before removing or
installing Mini-PIMs.