Juniper 1-Port SFP Mini-PIM SRX-MP-1SFP Manuale Utente

Codici prodotto
SRX-MP-1SFP
Pagina di 264
1-Port ADSL2+ Mini-Physical Interface Module Basic Configuration
To enable the 1-Port ADSL2+ Mini-Physical Interface Module (Mini-PIM) installed on the
SRX Series Services Gateway, you must configure its properties. You can perform the
same configuration tasks using either the J-Web interface or the CLI:
Using the J-Web Interface
To perform basic configuration for the 1-Port ADSL2 Mini-PIM and to configure network
interfaces for the services gateway using the J-Web interface:
1.
In the J-Web interface, select Configure>Interfaces>Ports.
The Interfaces page displays and lists the network interfaces present on the services
gateway, along with configuration information (if configured).
2.
To configure properties for a network interface (Mini-PIM), select the interface name
(at-1/0/0), and click Edit.
3.
To use the port on the Mini-PIM, you must assign it to a security zone other than the
Null zone. Optionally, you can also assign the port an IP address (for example,
192.168.3.1/24). Enter or select the following settings:
a.
Select Configure>Security>Zones.
b.
Add or select a security zone other than Null; for example, Trust.
c.
For host inbound traffic, set the following:
System Services=Allow All
Protocols=Allow All
d.
Click OK to save changes, and click Commit to apply the configuration and other
pending changes.
4.
To use the port on the Mini-PIM, you must also set security policies. Select the following
settings:
a.
Select Configure>Security>Policy>Apply Policy.
b.
Set Policy Action: Default Policy Action=Permit-All.
c.
Click OK to save changes, and click Commit to apply the configuration and other
pending changes (if any).
See the
for more details.
39
Copyright © 2012, Juniper Networks, Inc.
Chapter 3: 1-Port ADSL2+ Mini-Physical Interface Module