Netgear FSM750S – 48-Port 10/100 Mbps Managed Stackable Switch with Gigabit Ports Manuale Di Riferimento

Pagina di 123
Page 114 of 121 
3) 
Setup the Port VLAN IDs as follows.
 
 
Note
: Port 01 PVID is set to 2. This must be done in the port specific page since there is no VLAN with ID 2 
 
 
 
 
The specific ports above have the following Port VLAN ID settings (The Port VLAN ID settings for each port are configured in the VLAN Ports page): 
 
Port 01: 2    Port 05: 5 
Port 09: 10 
Port 13: 10 
Port 02: 1    Port 06: 1 
Port 10: 10 
Port 14: 15 
Port 03: 1    Port 07: 1 
Port 11: 10 
Port 15: 1 
Port 04: 1    Port 08: 1 
Port 12: 10 
Port 16: 1 
 
 
The following scenarios will produce results as described below: 
 
1)  If an untagged packet enters Port 4, the switch will tag it with a VLAN tag value of 1. Since Port 4 does not have membership with VLAN 
ID 1 (default), the packet will be dropped. 
 
2)  If a tagged packet with a VLAN tag value 5 enters Port 4, the packet will have access to Ports 5 and 1. If the packet leaves Port 5 and/or 
1, it will be stripped of its tag becoming an untagged packet as it leaves the switch. 
 
3)  If an untagged packet enters Port 1, the switch will tag it with a VLAN tag value of 2. It will then be dropped since Port 1 has no 
membership with VLAN ID 2. 
 
4)  If a tagged packet with a VLAN tag value 10 enters Port 9, it will have access to Ports: 1, 10, 11, and 12. If the packets leave Ports 1 or 
10, they will be tagged with a VLAN ID value of 10. If the packet leaves Ports 11 or 12, it will leave as an untagged packet. 
 
5) 
If a tagged packet with a VLAN tag value 1 enters Port 9, it will be dropped since Port 9 does not have membership with VLAN ID 1.