Netgear FSM750S – 48-Port 10/100 Mbps Managed Stackable Switch with Gigabit Ports Manuale Di Riferimento

Pagina di 123
Page 28 of 121 
Step 8: Connecting Devices to the Switch
 
The following procedure describes how to connect devices to the switch’s RJ-45 ports. Your NETGEAR Model FSM726S or FSM750S Managed 
Stackable Switch contains Auto Uplink™ technology, which allows you to attach devices using either straight-through or crossover cables. 
 
 
Figure 4-9: Connecting Devices to the Switch 
Connect each device to an RJ-45 network port on the switch’s front panel (see Figure 4-9). Use Category 5 (Cat5) unshielded twisted-pair (UTP) 
cable terminated with an RJ-45 connector to make these connections. 
Note
: Ethernet specifications limit the cable length between the switch and the attached device to 100 m (328 ft). 
 
Adding or Removing Switches to the stack
 
For the master unit to properly manage the stack, we recommend the following steps when adding or removing a switch from the stack 
1.     Power down all switches in
 
the stack.
 
Note
: Do not add or remove stacking cables while the switch is powered up. 
2.     Remove/Add the necessary switches
 
Note
: the Stack In port on the master unit is always empty. 
3.     Power up the slave units in the stack. 
4.     Power up the master unit