Zanussi ZHG513G Manuale Istruttivo

Pagina di 14
3
Part 1 - INSTALLATION INSTRUCTIONS
1 - GENERAL INFORMATION
This canopy hood is designed to be fitted into cabinets or chimney cooker hoods, placed above
a hotplate. It can be used either in the extraction mode (ducted to the outside) or in the recirculation
mode (internal recycling).
Before starting the installation, consideration should be given to the difficulties to be found
during installation. The installation work must be undertaken by a qualified and competent
person in conformity to the rules concerning the evacuation of contaminated air.
The manufacturer disclaims all liability for any damage or injury caused as a result of not
following the instructions for installation contained in the following text.
2 - SAFETY WARNINGS
2.1 - When used in the extraction mode, the cooker hood ducting must not be connected to a flue
which is used for exhausting fumes from appliances supplied with energy other than electric,
such as a central heating flue or water heating flue.
2.2 - Before connecting to the mains supply ensure that the mains voltage corresponds with the
voltage on the rating plate inside the hood.
2.3 - Connect the cooker hood to the mains via a bipolar switch which has 3mm clearance
between the contacts.
2.4 - The appliance must be earthed.
2.5 - When installed, the hood must be positioned at least 65 cm above the hotplate.
2.6 - Never do flambé cooking under this cooker hood.
2.7 - Never leave frying pans unattended during use as overheated fat and oil may catch fire.
2.8 - Before carrying out any kind of maintenance or cleaning, disconnect the hood from the
mains supply.
2.9 - If the room where the cooker hood is to be used contains a fuel burning appliance such as
a central heating boiler then this must be of the room sealed or balanced flue type. If other
types of flue or appliance are fitted, ensure that there is an adequate supply of air into the
room. When the cooker hood is used in conjunction with appliances supplied with energy
other than electric, the negative pressure in the room must not exceed 0,04 mbar to prevent
fumes being drawn back into the room by the cooker hood.
3 - INSTALLATION
The following scheme has to be observed:
3.1 - Installation of the built-in group
3.2 - Set the hood for recirculation or evacuation
3.3 - Connect the hood to the mains supply and ensure that it works properly
520 mm
700 mm
Side A
497 mm
677 mm
Side B
259 mm
259 mm
Cooker Hood
Dimensions