The parameters you include in this URL are dependent upon how you want the 
DHCT to process the xOD service. Each parameter is separated from the others by a 
semicolon (;). 
The previous example includes the following possible parameters that can appear in 
the Application URL: 
 
xOD client application path 
 
TunerInit 
 
EID 
 
level2 
 
SEL 
 
version 
 
argumentlist 
Each of these parameters is described in more detail in the following subsections. 
 
xOD Client Application Path (Required) 
The first parameter that appears in the Application URL indicates the path on the 
BFS server where the client application resides. This parameter tells the DHCT 
where to go to download the xOD application. In the case of xOD, this parameter is 
bfs://xod/CPU/saixod.ptv
 
TunerInit (Required) 
The TunerInit parameter tells the DHCT whether or not to play background audio 
when the subscriber tunes to the xOD catalog window. If you do not want to play 
background audio, set this parameter to false (TunerInit=false). 
 
EID (Required) 
The EID parameter identifies the xOD package in decimal format as determined in 
the previous section of this chapter, Create an xOD Package. For example, if the 
decimal value of the xOD service package is 31, you would set this parameter to 31 
(EID=31). 
Note: If you are registering a TIG channel, use the base xOD package EID. 
 
level2 (Required) 
The level2 parameter specifies whether or not the client application is able to allow 
Level 2 functionality, such as changing the volume with the remote control. Set this 