Toshiba MK1032GAX Manuale Utente

Pagina di 159
 
 
  Toshiba Corporation Digital Media Network Company 
 
Page 63 of 159 
© 2004, Copyright TOSHIBA Corporation All Rights Reserved
 
                   
 
 
11.8.9  Read Verify  (40h) 
 
 
COMMAND CODE 
0 1 0 0 0 0 0 0
REGISTER 
 
REGISTER SETTING 
NORMAL COMPLETION 
DR 
drive no. 
no change 
CY 
starting cylinder 
last possible 
HD 
starting head 
last possible 
SN 
starting sector 
start sector 
SC 
no. of sector to be read 
00H 
LBA 
starting address 
last address 
 
This command is identical to a Read command except that the drive has read the data from the media, and 
the DRQ bit is not set and no data is sent to the host.    This allows the system to verify the integrity of the 
drive.    A single interrupt is generated upon completion of a command or when an error occurs.   
   
11.8.10  Read Verify EXT    (42h) 
 
COMMAND CODE 
0 1 0 0 0 0 1 0
 
REGISTER 
 
REGISTER SETTING 
NORMAL COMPLETION 
DR 
 
drive no. 
no change 
LBA 
Low 
Current 
Previous 
LBA(7:0) 
LBA(31:24) 
HOB=0
HOB=1
last address 
last address 
LBA 
Mid 
Current 
Previous 
LBA(15:8) 
LBA(39:32) 
HOB=0
HOB=1
last address 
last address 
LBA 
High 
Current 
Previous 
LBA(23:16) 
LBA(47:40) 
HOB=0
HOB=1
last address 
last address 
SC Current 
Previous 
sector count(7:0) 
sector count(15:8) 
HOB=0
HOB=1
00H 
00H 
FT Current 
Previous 
reserved 
reserved 
HOB=0
HOB=1
no change 
no change 
 
 
This command is identical to a Read EXT command except that the drive has read the data from the media, 
and the DRQ bit is not set and no data is sent to the host.    This allows the system to verify the integrity of 
the drive.    A single interrupt is generated upon completion of a command or when an error occurs.   
This command is available in LBA addressing only. 
 
11.8.11 Write Verify
6
  (3Ch) 
 
   
                                                           
6
    ATA/ATAPI-4 defines this command as Vendor specific. The drive supports this command to maintain ATA-3 compatibility. User is 
recommended not to use this command.