Software settings
 
You will need to make audio and MIDI device settings for the software you’re using. Here are some examples 
for typical software applications.
In this example we are using SONAR 3 Producer Edition.
You must make the following settings if you have switched the FA-101's sample rate or have 
changed the buffer size in the FA-101 Driver settings dialog box.
 
1.
 
Power up the FA-101, and then start up SONAR.
 
2.
 
From SONAR’s 
 
Options
 
 menu, choose 
 
Audio
 
 to open the 
 
Audio Options
 
 dialog box.
 
3.
 
Click the 
 
Advanced
 
 tab.
In the 
 
Playback and Recording
 
 area, verify that 
 
Driver Mode
 
 is set to 
 
Use Default
 
 or   
 
WDM/KS
 
.
If you change this setting, click 
 
[OK]
 
 and restart SONAR.
 
4.
 
Restart SONAR, and from the 
 
Options
 
 menu, choose 
 
Audio
 
 to open the 
 
Audio Options
 
 dialog box.
 
fig.sonar-1.eps
 
5.
 
In the 
 
General
 
 tab, set 
 
Audio Driver Bit Depth
 
 to 
 
24
 
Set the 
 
Sampling Rate
 
 to the same setting as the FA-101’s sample 
rate select switch.
If you change this setting, click 
 
[OK]
 
 and exit SONAR.
 
fig.sonar-4.eps
 
* If the 
 
Audio Driver Error
 
 dialog box appears, click 
 
[Use Anyway]
 
If you click 
 
[Disable]
 
, the setting will be discarded.
 
6.
 
Restart SONAR, and from SONAR's 
 
Options
 
 menu, choose 
 
Audio
 
 to open the 
 
Audio Options
 
 dialog box.
 
7.
 
In the 
 
General
 
 tab, click 
 
Wave Profiler
 
.
When 
 
Wave Profiler
 
 is finished, click 
 
[OK]
 
.
 
SONAR 3