Minicom Advanced Systems 116 IP Manuale Utente

Pagina di 56
USER GUIDE 
42 
 
Figure 39 Time settings window 
 
26.6.1 Scan (SCN) - Label (LBL) - Time out (T/O) 
SCN - In the SCN column, change the scan period.  
LBL - In the LBL column, change the display period of the Confirmation label 
showing which computer is currently accessed. 
T/O - When password protection is activated you can automatically disable the 
Management keyboard, mouse and screen after a preset time of non-use. Set this 
Timeout period in the T/O column. 
 
To set the above periods: 
1.  On the desired line press Tab to jump to the desired column.  
2.  Place the cursor over one of the 3 digits and type a new number. Enter a leading 
zero where necessary. For example, type 040 for 40 seconds. 
Typing 999 in the LBL column displays the label continuously. Typing 000 – 
the label will not appear. 
Typing 999 in the T/O column disables the Timeout function. Typing 000 – the 
Timeout function works immediately. 
Typing 999 in the SCN column displays the screen for 999 seconds. Typing 000 
– the computer screen is skipped. 
26.7 Users 
In the Settings window navigate to the Users line and press Enter. (Note! Users is 
only enabled if the security status is set to On, see page 39). The Users settings 
window appears see Figure 40.