Minicom Advanced Systems 116 IP Manuale Utente

Pagina di 56
USER GUIDE 
52 
2.  Select Options/Advanced/Reset. The unit resets. The system should now be 
operational. 
28.2 Setting default values for the OSD  
To return the OSD to the factory default settings: 
Select Options/Advanced/Set Default. A warning appears, click OK. The OSD 
returns to the factory default settings. 
28.3 Get Status 
If there is a break in communication between the Update software and the system, 
select Options/Get Status to get the current status of the computers in system. 
28.4 Communication Error message 
When updating a unit and a Communication Error message appears, do the 
following: 
1.  Check that the RS232 Serial cable’s RS232 connector is connected to the 
Switch’s Flash port. 
2.  Check that the RS232 Serial cable’s DB9F connector is connected to the 
laptop’s Serial port. 
3.  Verify there is no Remote session in progress by pressing the Local button. 
4.  Restart the update process. 
28.5 Electricity failure  
When the electricity fails while updating the Smart 116 IP firmware, do the 
following: 
If the electricity fails during the firmware update of the Switch, a Communication 
Error
 message appears. Simply resume the firmware update by opening the folder 
that contains the firmware update file and continue from there. 
If the electricity fails during the firmware update of the RICCs a Not Responding 
or Upgrade Error message appears. Restart the upgrade from the beginning. 
 
(For electricity failure during a firmware upgrade of the digital part of the Smart 
116 IP, see page 33).