NOTE: 
Before starting radar setup, take your vessel out on open water 
with fairly calm seas, like an open bay. 
The three setup features we want to modify are Adjust Trigger Delay, 
Adjust Main Bang Suppression and Adjust Heading Line.  
We will set them up in that order, but before making any adjustments, 
make sure the display is set to a range of 0.125 nautical miles and that 
Gain, Anti-Sea Clutter (STC), Anti-Rain Clutter (FTC), Main Bang 
Suppression and Trigger Delay all have been set to zero percent. 
Trigger Delay Preparation 
Range 
1. To reset range to 0.125 nm, make sure you are on the Radar Only 
page and press 
MENU
.  
2. Use 
↑ ↓  to select 
R
ADAR 
R
ANGE
 and press 
ENT
, which will call up the 
Radar Range list. Press 
↑ to select 0.125 nm and press 
ENT
. You also 
can set the range to 0.125 nm from the radar screen by using the 
ZIN
 
and 
ZOUT
 keys. 
Gain 
1. To set Gain to zero, press 
MENU
, select 
G
AIN
 and press 
ENT
.  
2. That will launch the Gain vertical scrollbar. Press 
↓ until the Gain is 
set to zero percent. Press 
EXIT
. (Notice the corresponding value in the 
upper right-hand corner of the screen.)  
NOTE
When adjusting Gain back to a useable level, increase the level un-
til you see a light peppering on the display. Also remember, you will 
have to adjust gain every time you change ranges. 
Anti-Sea Clutter 
1. To set Anti-Sea Clutter to zero, press 
MENU
, select 
A
NTI
-S
EA 
C
LUTTER 
(STC)
 and press 
ENT
.  
2. That will launch the Anti-Sea Clutter vertical scrollbar. Press 
↓ until 
the Anti-Sea Clutter is set to zero percent. Press 
EXIT
. (Notice the cor-
responding value in the upper right-hand corner of the screen.) 
Anti-Rain Clutter 
1. To set Anti-Rain Clutter to zero, press 
MENU
, select 
A
NTI
-R
AIN 
C
LUTTER 
(FTC)
 and press 
ENT
.