Mitel Deutschland GmbH 68635RFP36U-01 Manuale Utente

Pagina di 383
 
SIP-DECT OM System Manual 
 
 
244 
Note that the user_common.cfg file is loaded from the ConfigURL and the specific URL when both URLs 
are set. 
 
Configuration / Resource 
File 
Location of Specific URL 
OMM Web Service 
OMP 
user_common.cfg / <user>.cfg 
N/A 
System > Data management User data 
import 
See section 6.5.7.2. 
ima.cfg 
System > System settings > OM 
Integrated Messaging & Alerting service 
See section 5.4.1. 
System > Advanced settings > IMA 
See section 6.5.2.4. 
iprfp3G.dnld 
System > System settings > Software 
update URL  
See section 5.4.1.10. 
System > Basic settings > Software 
Update URL  
See section 6.5.1.4. 
600.dnld 
System > System settings > DECT 
phone’s firmware update  
See section 5.4.1.6. 
System > Advanced settings > PP 
firmware 
See section  6.5.2.3.
 
customer_image.png 
N/A 
System > Advanced settings > Special 
Branding  
See section 6.5.2.7 
 
7.8.3  RELOAD OF CONFIGURATION AND RESOURCE FILES 
The OMM automatically tries to load all configuration and resource files (ipdect.cfg, <MAC>.cfg, 
PARK.cfg, ima.cfg, user_common.cfg, update check for iprfp3G.dnld, etc) from the retrieved ConfigURL 
or specific URL (if present in the OMM database) at startup. 
In addition, the OMM supports several mechanisms for updating the configuration by triggering a reload 
of the configuration and resource files: 
• 
DHCP lease time 
If the OMM is running on a RFP and DHCP is used, all configuration and resource files are reloaded 
when half of the DHCP lease time has elapsed. 
• 
Daily automatic reload of configuration and firmware files 
You can enable this option and specify a specific time of day to reload configuration files via the OMM 
Web service or the OMP (System -> Provisioning -> Daily automatic reload of configuration and 
firmware files).  
• 
Manual reload via 
Update button 
You can trigger a manual reload of all configuration and resource files by clicking the 
Update button 
in the OMM Web service (
System ->System settings page ) or OMP (System -> System settings   
-> 
General tab).  
• 
600 DECT phone Administration menu 
-  When a user with a 600 DECT Phone selects the 
Sync system data option in the Administration 
menu, the OMM reloads all configuration and resource files. 
-  When a user with a 600 DECT Phone selects the 
Sync user data option in the Administration 
menu, the OMM reloads the <user>.cfg file for that user.   
• 
SIP Notify message