When the OMMs get in contact again: 
• 
Both OMMs check which one ran for a longer period. That one will become the active OMM. The 
other one falls back to the standby one.  
 
7.15.3 FAILOVER FAILURE SITUATIONS 
Failover failure occurs when the connection between OMMs fails and the configured SIP Proxy/Registrar 
is unreachable. In this case the active OMM waits until the SIP Proxy/Registrar is reachable. 
The following state diagram shows the OMM Standby states: 
 
OMM sync OK”: OMMs are synchronized and are able to exchange their operational states 
OMM sync NOK”: OMMs are not synchronized and are not able to exchange their operational states 
*1) In this state the DECT air interface might not be in a definite state as both OMMs are active but cannot 
connect with each other! This is caused by IP network failures and cannot be handled by the SIP-DECT system in 
a proper automatic way. In such a scenario it is not predetermined which RFP connects with which of the 2 
OMMs. The DECT network can split-up into two unsynchronized DECT sub-networks. This can cause voice 
quality and handover problems.