Mitel Deutschland GmbH 68635RFP36U-01 Manuale Utente

Pagina di 383
 
SIP-DECT OM System Manual 
 
 
272 
Each of this these access types uses the same account data.  
The account data can be altered at the 
User account page of the OMM Web.  
The OMM delivers all the necessary account data to all connected RFPs. The RFPs save the account 
data inside their permanent memory. This has some implications: 
• 
An RFP out of the box uses the default account data as long as this RFP is not connected to the 
OMM. 
• 
An RFP which was connected for at least one time with the OMM uses the account data from the 
OMM. 
• 
When the account data are changed on the OMM, any not connected RFPs will continue to use the 
older passwords. 
 
7.17.1 ACCOUNT TYPES  
There are three different account types: 
• 
Full access: This access type is the “normal” access for the configuration. Using this access it is 
allowed to configure the OMM and each RFP. On the SSH interface of an RFP this access type 
allows login for debug information e. g. “pinging” another RFP to check visibility. 
The factory setting for this account is 
Name:  
'omm' 
Password:  'omm' 
Active: 
'n/a' 
• 
Read-only access: As the name suggests this access type is not allowed to configure any item of the 
OMM installation. This access type can only be used on the OM Web service. The account can be 
deactivated.  
The factory setting for this account is 
Name:  
'user' 
Password:  'user' 
Active: 
'yes 
• 
Root (SSH only) access: This access type is only applicable on the SSH interface of an RFP. Its 
purpose is to get detailed information e. g. parameters from the kernel. The access using this account 
type is not reachable from other hosts hence a login using the full access type is necessary. 
The factory setting for this account is 
Name:  
'root' 
Password:  '22222' 
Active: 
'n/a' 
Please note: 
It is highly recommended not to use the “Root (SSH only) access” account 
type. It is meant for technical support only. 
 
7.17.2 POTENTIAL PITFALLS 
When an RFP is configured via the OM Configurator and is taken out of an installation, the RFP may 
become unusable: