Mitel Deutschland GmbH 68635RFP36U-01 Manuale Utente

Pagina di 383
 
Enhanced Feature Overview 
 
29 
Please note: 
To provide each user and/or conference room with a unique port using the 
port calculation, the port range must be greater than or equal to the number of users or 
conference rooms. 
 
Configuration Rules for Port Ranges 
Please note the following configuration rules for configuration of the UDP/TCP and TLS port ranges: 
• 
Port ranges for users and conference rooms may not overlap.  
• 
A port range configured outside the defaults (5060, 5061, 4060, 4061) can be within the range 
17000 – 32767.  
• 
Port ranges may not overlap with the ports of other OMM services. See section 9.7 for a list of all 
ports and protocols. 
• 
If the OMM is running on a DECT base station, the ranges may not include ports used by other DECT 
base station protocols. See section 9.7 for a list of all ports and protocols. 
• 
The port range for conference rooms is limited to 100 ports. 
• 
The port range for users is limited to the following: 
RFP OMM: maximum 512 ports 
Linux Server OMM: maximum 10,000 ports 
 
3.8  MIXED BASE STATION INSTALLATIONS 
In sites (or whole systems) with Hi-Q audio disabled, any combination of RFP 32/34 IP / RFP 42 WLAN 
and RFP 35/36/37 IP / RFP 43 WLAN is allowed. Note, however, that some security features are not 
supported for all DECT base stations (i.e., SRTP is supported on 3G RFPs only, enhanced security is 
available with RFPs 35/36/37/43). 
RFP SL35 IP support  
SIP-DECT supports the RFP SL35 IP after applying the unlock file and the standard SIP-DECT software 
to the DECT base station. 
Before the standard SIP-DECT software can be installed on the RFP SL35 IP, the unlock.xml file must 
be available for the DECT base station on the USB. After applying the unlock.xml file the DECT base 
station accepts the standard SIP-DECT software. 
In terms of licensing, the OMM manages the RFP SL35 IP with the unlock file and the standard SIP-
DECT software like an RFP 35 IP. 
For a detailed description see section 7.30. 
3.9  DECT XQ 
The DECT radio communication generally suffers from attenuation and radio wave reflection. In 
particular, if a building’s walls and ceilings contain a higher portion of metal-based material or if larger 
metal surfaces are present, the DECT XQ improves the radio communication between a DECT base 
station and a Mitel 600 DECT phone at the expense of DECT channel capacity (see 7.3). Enable this 
feature for some or all of your DECT base stations (see section 5.6.3, “DECT settings” or section 6.7.1.2, 
“DECT tab”). 
DECT XQ audio cannot be combined with Hi-Q audio within the same connection.