The SGET is part of Linear PRO Access control product line. In a typical 
installation, the SGET is mounted on a motorized gate, door or barrier arm and 
wired to a 10K exterior safety edge sensor which presents a closed circuit across 
the connecting wires when an object is hit during the closing of a gate. To insure 
full compatibility with all gate edge supervision features, Linear recommends Miller 
gate edge sensors with 10K only. Please specify when ordering sensor. If the edge 
sensor is pressed for 1/4 second, the SGET transmits a message to the SGER to 
reverse the movement of the gate. 
The SGET circuit board has been coated to prevent moisture damage and is 
mounted inside a weather resistant fiberglass box. The mounting box attaches to 
the gate through sealed interior mounting screws.
TYPICAL INSTALLATION
Loosen the four screws on transmitter top and remove cover. Install 2 “C” size 
batteries at this time.
Refer to diagram below for transmitter parts location and details.
Mount safety edge according to manufacturer’s instructions included with the 
product.
Choose a location as high as possible on gate in a secure position. Use the 
template attached to mark the location for the transmitter. You may have to 
attach a metal or wood plate to mount transmitter. Use a 3/32” bit and drill 
holes. Attach SGET to gate using the four #6 self-tapping drill point screws.
Unscrew the cable grip about 3/4 of the way and thread the safety edge cable 
through the cable entry on the transmitter.
Attach safety edge cable to terminals as shown. Tighten cable grip assembly 
using pliers to assure a water tight seal.
SGET
DIGITAL GATE 
Transmitter
Installation Instructions
PRO ACCESS
TM
Linear PRO Access • 3121 Hartsfield Road • Tallahassee, FL 32303
1.800.543.4283 • linearproaccess.com
Description
STEP 2     Remove Cover and Install Batteries
STEP 4     Mount SGET
STEP 5     Assemble Cable Grip
STEP 6      Attach Cable
STEP 1     Locate Parts
STEP 3    Mount Safety Edge
REMOVE
COVER
INSTALL
“C” BATTERIES
SGET
TRANSMITTER
SAFETY EDGE
SENSOR
GATE
OPERATOR
CABLE GRIP
ASSEMBLY
TO SAFETY
EDGE
TO SAFETY
EDGE
ATTACH EDGE
SENSOR CABLE
TO TERMINALS
1.77”
3.88”
WELD PLATE
TO GATE
ATTACH SGET
TO GATE
INSTALL
SAFETY EDGE
“C” Size
Battery Holders
Programming Button
Antenna
Wire
Terminals
PRINTERS INSTRUCTIONS 
 INSTR,INSTL,SGER SERIES - GTO P/N: 
10016915 
- INK:  BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 8.500” X 11.000” -  SCALE: 1-1 - SIDE 1 of 2