Toshiba IK-TF7P2 Manuale Utente

Pagina di 40
31
RR (Reset restart)
( 5 ) 
Input of an external reset-restart signal (CC4 of the DIGITAL terminal: External VD input) permits one screen of 
information to be output at an arbitrary timing.
Long Term Exposure
(5. 1) 
When sufficient sensitivity is not obtained under normal operating conditions or capturing the trail of a moving object 
is desired, the reset-restart function allows high-sensitivity images by extending the exposure time. To achieve this, 
please input (from an external source) a VD signal that has an expanded VD pulse and VD pulse interval.
Input Timing Chart Example
(5. 2) 
External HD IN
External VD IN
(Internal VD)
About 1H
V reset
Exposure period
Exposure period
Exposure period
About 1H
V reset
FVAL
1 frame
RGB data
(video interval image)
LVAL,
DVAL 
1 frame=  796H (Partial scanning OFF)
 
580H (Partial scanning 40fps)
 
553H (Partial scanning 42fps)
 
465H (Partial scanning 50fps)
 
387H (Partial scanning 60fps)
 
332H (Partial scanning 70fps)
 
290H (Partial scanning 80fps)
 
258H (Partial scanning 90fps)
Note:
External VD interval: more than 1 frame