Warm Start
This refers to restarting the system without turning the power off. When performing a
warm start, the EKI-1500 series will send an e-mail, or send a SNMP trap after
restarting the system.
Authentication failure
The user types a wrong password from Console or Administrator. When authentica-
tion failure
Occurs, the EKI-1500 series will send an e-mail, or send a SNMP trap.
IP Change
The user changes the EKI-1500 series’s IP address. When the IP address changes,
the EKI-1500 series will send an e-mail, or send a SNMP trap after restarting the sys-
tem.
Password Change
The user changes the EKI-1500 series’s password. When the password changes, the
EKI-1500 series will send an e-mail, or send a SNMP trap after restarting the system.
Ethernet 1 Down
The Ethernet 1 port has link failure condition. When the Ethernet 1 links fail, the EKI-
1500 series will send an e-mail, or send a SNMP trap immediately.
Ethernet 2 Down
The Ethernet 2 port has link failure condition. When the Ethernet 2 links fail, the EKI-
1500 series will send an e-mail, or send a SNMP trap immediately.
3.7.4
Serial Port Event