Advantech EKI-1524 4-Port RS-232/422/485 Serial Device Server EKI-1524-AE Scheda Tecnica

Codici prodotto
EKI-1524-AE
Pagina di 92
EKI-1521/1522/1524 User Manual
56
2.
Select which COM port you want to run a diagnostic test, and then press “Test” 
button to process the testing.
Signal Test
„
RTS -> CTS check the RTS and CTS signal between two ports
„
DTR -> RI check the DTR and RI signal between two ports
„
DTR -> DSR check the DTR and DSR signal between two ports
„
DTR -> DCD check the DTR and DCD signal between two ports
Communication Parameters Test
„
Baud rate    50bps ~ 921.6kbps
„
Data bit        5, 6, 7, 8
„
Stop bit        1, 1.5, 2
„
Parity           Odd, Even, None, Space, Mark
When the test is finish, it will show the test result, the click “Exit” button to return to
the utility window.