Figaro TGS2610-C00 TGS 2610 Gas Sensor For LP Gases Alcohol, Methane, Propane, Iso-Butane (Ø x H) 9.2 mm x 7.8 mm TGS2610-C00 Scheda Tecnica

Codici prodotto
TGS2610-C00
Pagina di 13
Revised 03/06
8
TECHNICAL INFORMATION FOR TGS2610
2-7   Long-term characteristics
Figure 13 shows long-term stability of TGS2610 as
measured for more than 900 days.  The sensor is first
energized in normal air.  Measurement for
confirming sensor characteristics is conducted under
standard test conditions.  The initial value of Rs was
measured after two days energizing in normal air at
the rated voltage.  The Y-axis represents the sensor
resistance in air, 3500ppm of methane, 1500ppm of
iso-butane, and 3500ppm of hydrogen.
The Rs in iso-butane is very stable over the test
period.
Figure 14 shows the influence of storage in an
unenergized condition on the sensor’s resistance.  The
sensors were stored unenergized in air after 20 days
energizing, then energized for one hour before a
measurement was taken.
As the charts presented in this section illustrate, the
sensor shows stable long term characteristics.
NOTE:
The MTTF (Mean Time to Failure) can be estimated
from this data.  Please refer to the Technical Advisory
MTTF Values of Figaro Gas Sensors.
0.1
1
10
100
0
200
400
600
800
1000
Air
Iso-butane 1500ppm
Methane 3500ppm
Hydrogen 3500ppm
Rs (k
Ω
)
Elapsed time (days)
1
10
100
0
200
400
600
800
1000
Air
Iso-butane 1500ppm
Methane 3500ppm
Hydrogen 3500ppm
Rs (k
Ω
)
Elapsed time (days)
0.5
Sensor unpowered
Fig. 13 - Long-term stability (continuous energizing) of
TGS2610-C
Fig. 14 - Influence of unenergizing on TGS2610-C