SERVICE (cont.)
LIMIT THERMOSTAT
FIG. 23 LIMIT THERMOSTAT
P2635
Location:
The limit thermostat is located in the center of the
tank lid.
Test Procedures:
1.
Disconnect the dispenser from the power source.
2.
Disconnect both black wires from the limit ther-
mostat.
3.
Check for continuity across the limit thermostat
terminals.
If continuity is present as described, the limit thermo-
stat is operating properly.
If continuity is not present as described, replace the
limit thermostat.
FIG. 24 LIMIT THERMOSTAT TERMINALS
P1800
BLK to Tank Heater
BLK to Control
Thermostat
35135 012103
Removal and Replacement:
1.
Remove all wires from the limit thermostat ter-
minals.
2.
Carefully slide the limit thermostat out from un-
der the retaining clip and remove the limit ther-
mostat.
3.
Carefully slide the new limit thermostat into the
retaining clip.
4.
Refer to Fig. 24 when reconnecting the wires.