Troubleshooting 
 
Problem Cause 
Solution 
Unit does not operate 
Input voltage is below 
10 volts 
Attach to proper supply 
 
Fuse blown 
Determine cause for fuse blowing 
and then replace fuse feeding 
inverter.   
Unit operates for a 
short period and 
then turns off 
Load is trying to draw too 
much current 
Be sure load is less than rated watts 
of inverter. Remove excessive 
load. Turn inverter off and back 
on to reset.  
Unit operates for a 
while and gets warm 
Inverter is in thermal 
shutdown mode 
Allow inverter to cool down. Turn 
inverter off and back on to reset. 
Low battery alarm is 
on 
Input voltage is below 
10.2 volts 
Make sure car engine is running. 
Check condition of wiring. 
Battery may be low and needs 
recharging. 
Television and stereo 
interference 
RF interference from 
power inverter 
Position the power inverter and 
wiring as far as possible from 
electronic equipment, antenna and 
cables and reorient as necessary. 
 
115 VAC Output 
voltage reads 
incorrectly 
Modified sine wave 
output can cause 
incorrect reading on a 
typical multimeter 
Use a true RMS meter like a Fluke 
8060A or Triplett 4200 to measure 
correct voltage. 
 
Light Status Chart 
Power 
Switch 
Power 
Light 
Beeper Fan  Fault 
Light Mode 
Off 
Off 
Off 
Off 
Off 
Unit is off 
On On  Off 
On 
Off Normal 
Operation 
On On  On On  Off 
Low input voltage, 10.2 to 9.7 volts 
On On  On On 
On 
Low input voltage, less than 9.7 volts 
On On  Off 
On On High Input voltage, greater than 15V 
On On  Off 
On 
On 
Unit over temperature or overloaded  
On 
Off 
Off 
Off 
Off 
No 12 VOLTS input to inverter 