Pertech A470 Manuale Utente

Pagina di 36
A470 Users Guide
Pertech® 2006
17
Pin # Cash 
Drawer A
Cash 
Drawer B
1
N /C
Solenoid +
2
Solenoid +
N /C
3
Solenoid -
Solenoid -
4
Switch
Switch
5
Switch
Switch
6
N /C
N / C
Each cash drawer driver will source 24 volts for 75 ms to the  “solenoid +” pin of the appropri-
ate RJ-11 jack when the proper cash drawer command is executed. The cash drawer com-
mand must be preceded by a line terminator. The command for the cash drawer may vary for 
the Compatibility Mode selected.  
Cash Drawer
Warning: This Printer is designed for use only with Pertech Resources A470 / DH Tech-
nology 4700 compatible cash drawers. Damage can result if the A470 is connected to a 
cash drawer that is incompatible. The cash drawer solenoid resistance must be at least 
25 ohms or damage to the printer could result. 
Synopsis
ASCII
Hex
Decimal
Cash Drawer “A”
ESC  BEL
1B  07
27  7
Cash Drawer “B”
ESC  BS
1B  08
27  8
A470 Command Language Cash Drawer Commands
Power Supply
The A470 printer uses a NTRL Certified external switching power source with a Limited Power 
Source (LPS) output for use in North America,  input 100-240 Vac, 50/60 Hz, 1.5 A, with a 
maximum power consumption of 60 watts, output is rated at 24 Vdc,2.5A. 
The power cable connector is a Mini-Din Barrel Connector and is located at the back or the 
printer. 
Use of this product with a power supply other than the Pertech power supply will require you 
to test this power supply and Pertech printer for FCC and CE mark Certifications. ( See FCC 
Radio Frequency Interference Statement on page iii of this manual).