Pearson 70 Manuale Utente

Pagina di 48
Scanner Installation
Installing the Scanner
2-9
Logic Voltage Check-out Procedure
The outputs of the power supplies are read at their most critical point-the input to 
the Camera Controller Board, the Solenoid Clutch Activation Board, and the Top 
LED Mother Board.
1.
Turn on the scanner power switch.
2.
Use a DVM to measure the outputs to the voltages listed in Table 2-4. Be sure 
to connect your ground probe to TPG1, TPG2, TPG3, or TPG4 on the Camera 
Controller Board.
+12V Boost Power Supply
There are no adjustments to the +12V, 200W boost power supply. If its output is 
not +12.5V to 16V, replace the supply.
Location of the Power Supplies 
Figure 2-1 and Figure 2-2 illustrate the location of the power supplies and the 
location of the adjustment potentiometers. The power supplies that may require 
checkout and periodic adjustments are:
+12V, 250W, Solenoid and DC Motors Power Supply (adjusted to +12.5V)
+5V LED Power Supply
+5V and ±15V Logic Power Supply
Note:
The Logic Power Supply is labeled ±12V, but it should be adjusted to ±15V.
Table 2-4  Logic Voltages
Nominal 
Voltage
Camera 
Controller Pin 
Location
Solenoid Clutch 
Activation 
Board (SCAB 
Pin Location
Top LED 
Mother Board 
Pin Location
Acceptable Range
+5V
J5 - 3
+4/95 to + 5.20V DC
-15V
J5 - 1
-15 to - 15.20V DC
+15V
J5 - 2
+15.0 to -15.20V DC
Ground
TPG1, TPG2, 
TPG3, TPG4
+12.5V
J9 - 4
+12.5 to +13V
+V Boost
J9 - 7
+12 to +16V
+5V
J3 - 1
+5 to +5.5V