Pearson 70 Manuale Utente

Pagina di 48
Installation of Host Computer and Peripherals
Standalone Installation
3-4
Installation Guide for the OpScan iNSIGHT 70 Scanner
7.
Complete installation of one 9-pin D cable from the Scanner Controller main 
board to the  Com1 port on the back of the computer.
One end of this cable is already attached to the scanner's Scanner 
Controller
 main board at J9.
Connect the other end to the Com1 port on the back of the computer.
Once all computer cabling connections have been made, set the computer on the 
shelf, coil any extra cabling under the computer shelf, and close the rear panels.
Work Table
The standalone OpScan iNSIGHT 70 scanner comes with a work table. This work 
table is for the monitor, the keyboard, and the mouse. Instructions for assembling 
the work table are provided by the manufacturer.
Monitor and Keyboard
Place the monitor, the keyboard, and the mouse on the work table. The monitor, 
the keyboard, and the mouse need to be cabled to the computer. (See Figure 3-5 
for cable locations.)
Monitor
1.
Connect the power cord:
Plug the female end of the power cord into the port labeled AC Outlet on 
the back of the monitor.
Plug the other end (male end) into an AC wall outlet or power strip.
2.
Ensure that the monitor cable is connected. (See Step 6 under cabling.)
3.
Complete 5 BNC cable install from the bulkhead to the back of the monitor.
Connect one end of this cable to the bulkhead. Install the cable according 
to the colors labeled on the bulkhead.
Connect the other end (15-pin) to the back of the monitor.
Keyboard and Mouse
1.
Plug the keyboard cable connector into the port labeled KEYBOARD located on 
the scanner's back panel (bottom and second cutout from the left).
2.
Plug the mouse cable connector into the port labeled MOUSE located on the 
scanner's back panel (bottom and second cutout from the left).