Home Automation OmniPro II Manuale Utente

Pagina di 100
Status 
 
The Status function is used to display the status of various items in the system.  To enter the status menu, from the top-level 
display or the main menu, press the 6 (STATUS) key on the console keypad. 
 
   STATUS
 
 
 
 
1=CTRL  2=ZONE 3=SUN   
↓ 
 
   4=TEST 
 
5=TEMP 
6=ENERGY
 
 
 
 
                       
↑ 
1 = CTRL (CONTROL UNITS)
 
 
The Control Status menu allows you to view and scroll through the status of each control unit and to configure HLC and UPB 
devices.  To enter the Unit menu, from the Status menu, press the 1 (CTRL) key in the console keypad.  The system will display: 
 
   DEN 
LAMP
 
 
 
 
STATUS  OFF            
 
 
You may enter a unit number to start displaying the status of that unit, or simply press the down arrow key to scroll through the 
list of units.  The status display is as shown under Control, except that now the arrow keys may be used to continue scrolling 
between units. 
 
 
 
 
Porch Light     00:24:19
 
 
 
 
LAST COMMANDED  ON     
 
 
You can also check the state and (if any) the remaining time duration of any Unit. 
 
At this point, you may press the ' # ' key to control the unit as specified under Controlling Units or press ' # # ' to configure and 
HLC or UPB device. 
 
Note: Only HAI manufactured UPB™ devices (collectively referred to as HLC devices) can be configured using an OmniPro II 
controller.  Other UPB™ devices may be used, but cannot be configured using the OmniPro II controller; they must be configured 
using a PC running the UPB™ UPStart configuration software. 
 
 
Configuring HLC Devices 
 
HLC devices can be configured using an Omni console or OmniTouch touchscreen connected to the OmniPro II controller.  
When configuring HLC devices, the following information is programmed into the HLC device:  
 
¾  Network ID (UPB Network ID configured in OmniPro II controller) 
¾  Network Name (HAI Lighting) 
¾  Unit ID (Unit Number of respective unit) 
¾  Unit Name (which is the name description given to the respective unit in the OmniPro II controller) 
¾  Room Name (using HLC, the name of the first unit in the respective group is used; otherwise the room number is used) 
¾  Links (every device in each room is programmed with 6 consecutive Links, starting with Link 1; for example, every device 
in Room 1 is programmed with Links 1-6, Room 2 is programmed with links 7-12, etc.) 
¾  Other configuration information 
 
When configuring HLC devices using an Omni console or OmniTouch touchscreen, each device (unit number) must first be 
assigned a name in the OmniPro II controller.  HAI recommends that you first configure your OmniPro II controller (naming all 
of the HLC units) using the HAI PC Access Software, and then download the information to the OmniPro II controller. 
 
 
Configuring HLC Devices using an Omni Console 
 
To configure HLC devices from an Omni console, use the Status menu.  To enter the Status menu, from the top-level display or 
the main menu, press the 6 (STATUS) key on the console keypad. 
 
   STATUS
 
 
 
 
1=CTRL  2=ZONE 3=SUN   
↓ 
 
Page 36