3.  External Connections 
1
2
3
4
9
10
V-
V+
G
V-
V+
SH
D_L
D_H
6
5
7
8
11
13
12
 
Figure 2 - Terminal Blocks and Connectors 
 
ID 
Label 
Description 
Output 1 
Contact will close if in open mode or to start the conveying system. 
Maximum load 1A @24VDC, 0.5A@120VAC 
Output 2 
Contact will close if in close mode or to stop the conveying system.  
Maximum load 1A @24VDC, 0.5A@120VAC 
Output 3 
Contact will close if all setpoints are at zero.  
Maximum load 1A @24VDC, 0.5A@120VAC 
Output 4  
Contact will close if the interface has an internal fault.  
Maximum load 1A @24VDC, 0.5A@120VAC 
Inputs 1 
Energizing will select open mode. 
Inputs 2 
Energizing will select close mode. 
Inputs 3 
Energizing will clear all setpoints to zero. 
Inputs 4 
Energizing will force all actuators closed without affecting open/close 
mode selection.  Blending timers are ignored during a force close.