Avaya Media Gateway G700 Manuale Utente

Pagina di 768
Telephones and adjunct systems
366 Installing and Upgrading the Avaya G700 Media Gateway and Avaya S8300 Media Server
 
Local and Phantom Power
An attendant console’s maximum distance from the system is limited. 
See 
1152A1 mid-span power distribution unit
The 1152A1 Mid-Span Power Distribution Unit (PDU) is an Ethernet power supply that provides 
power to up to 24 46xx-series IP telephones or wireless LAN (WLAN) access points. This unit is 
used with a 10/100BaseTx standard Ethernet network over a standard TIA/EIA-568 Category 5, 
6 or 6e cabling plant. The 1152A1 meets the current requirements of the IEEE802.3af standard 
for resistive detection.
The 1152A1 PDU complies with the Underwriters Laboratories Inc. (UL) standard UL 1950, 
second edition. 
For safety instructions, see 
installation instructions, see 
Table 21: Attendant Console Cabling Distances
Enhanced Attendant 
Console (302D) 
24 AWG Wire (0.26 
mm
2
)
26 AWG Wire (0.14 
mm
2
)
Feet Meters
Feet Meters
With Selector Console
Phantom powered
800
244
500
152
Locally powered
5000
1524
3400
1037
Without Selector 
Console
Phantom powered
1400
427
900
274
Locally powered
5000
1524
3400
1037
Table 22: 1152A1 PDU UL 1950 Compliance 
Complies
UL 1950
Approved
CSA C22.2 No.950 Std.
Approved
CE Regulatory 
Compliance
Approved
EN 60950
Approved
TUV EN 60950