Stage C - Reconfigure the LOCAL connections and begin
1  On the computer from which you will run the upgrade, ensure that its BIOS 
settings will allow it to boot from the floppy diskette drive, rather than 
booting immediately from the hard drive.
2  Switch off the computer and disconnect the twisted pair cable from the 
LOCAL module.
3  On the multi-cable, leave the 
keyboard connector attached 
to the keyboard port of the 
computer. Disconnect the 
multi-cable video and mouse 
connectors from the ports on 
the computer. 
4  So that you can check upgrade 
progress, connect a monitor 
directly to the video port of the 
computer.
5  On the LOCAL module, change switch 1 to the ON position. Ensure that the 
upgrade diskette is in the floppy disk drive of the computer.
6  Switch on the computer. The upgrade process will start automatically and 
confirmation will be given on screen.
7  Switch off the computer and disconnect the multi-cable. Leave the monitor 
connected and the upgrade diskette in the floppy disk drive. Return LOCAL 
switch 1 to the OFF position. 
   Now please follow Stage D.
Stage D - Reconfigure the REMOTE connections and begin
1  Disconnect all cables from the REMOTE module and take it to the computer.
2  Use a ‘KVM switch-type’ 
keyboard cable (6pin mini-DIN 
male to 6pin mini-DIN male plugs 
with all lines connected) - not 
supplied. Attach one end of the 
cable to the keyboard port of the 
computer. Connect the other end 
of the cable to the keyboard port 
of the REMOTE module. This is 
the only connection required.
3  On the REMOTE module, change 
switch 1 to the ON position.
4  Attach the power supply unit to the POWER input of the REMOTE module 
and connect the mains lead to a nearby wall socket. 
5  Switch on the computer. The upgrade process will start automatically and 
confirmation will be given on screen.
6  Switch off the computer and disconnect the REMOTE module. Return 
REMOTE switch 1 to the OFF position.
Now please follow Stage E. 
Stage E - Return all connections to their usual states
Once the upgrade process has been completed, perform the following to return 
the system to its previous state.
1  Ensure that switch 1 on both the LOCAL and REMOTE modules are set to 
their OFF positions.
2  Refer to the ‘Installation and operation’ chapter for detailed instructions on 
correctly connecting the LOCAL and REMOTE modules to the computer, its 
peripherals, the REMOTE power supply and the twisted pair cable. 
3  Remove the diskette from the system and reboot. The upgrade process is 
now complete.   
PC
X2
LOCAL
AUDIO
VIDEO
KEYBOARD
MOUSE
RS232 SERIAL
Leave only the keyboard connection 
intact between the LOCAL module 
and the computer
Connect a video monitor 
to the computer so that 
you can check progress
PSU
PC
X2
REMOTE
AUDIO
VIDEO
KEYBOARD
MOUSE
RS232 SERIAL
Leave the video monitor 
connected to the computer
so that you can check progress
Use a KVM switch-type keyboard 
connection cable between the 
REMOTE module and the computer