Delta Tau GEO BRICK DRIVE Manuale Utente

Pagina di 294
 Geo Brick Drive User Manual 
Pinouts and Software Setup 
 141 
Yaskawa Incremental Encoder Alarm Codes 
 
Yaskawa Incremental encoder Alarm Registers 
Channel 1  Y:$78B22,8,8  Channel 5  Y:$78B32,8,8 
Channel 2  Y:$78B26,8,8  Channel 6  Y:$78B36,8,8 
Channel 3  Y:$78B2A,8,8  Channel 7  Y:$78B3A,8,8 
Channel 4  Y:$78B2E,8,8  Channel 8  Y:$78B3E,8,8 
 
Bit#  Error Name 
Type 
Alarm 
Type 
Clear 
Action 
Notes 
Fixed at “1” 
 
Encoder Error 
Alarm 
Session 
Flag 
Power 
cycle 
Encoder Error 
10 
Fixed at “0” 
 
11 
Position Error 
Alarm 
Session 
Flag 
Power 
cycle 
Possible  error  in  position  or  Hall 
sensor 
12 
Fixed at “0” 
 
13 
Fixed at “0” 
 
14 
Origin  not  passed 
flag 
Warning 
The origin has not been passed in this 
session yet 
15 
Fixed at “0” 
 
 
 
Set at zero